16 ETHERNET INSTRUCTIONS
16.6 Clearing Error Information
1571
16
16.6 Clearing Error Information
GP.ERRCLEAR, ZP.ERRCLEAR
These instructions turn off the LEDs and clear error information.
*1
*1 To turn off the LEDs, use the RJ71EN71 with a firmware version of "05" or later.
Execution condition
Setting data
Description, range, data type
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
Ladder ST
ENO:=GP_ERRCLEAR(EN,U,s,d);
ENO:=ZP_ERRCLEAR(EN,U,s,d);
FBD/LD
Instruction Execution condition
GP.ERRCLEAR
ZP.ERRCLEAR
Operand Description Range Data type Data type (label)
(U) GP.ERRCLEAR Start I/O number (first three digits in four-digit
hexadecimal representation) of own station or own
node
00H to FEH 16-bit unsigned binary ANY16
ZP.ERRCLEAR Start I/O number (first three digits in four-digit
hexadecimal representation) of own station or own
node
00H to FEH String ANY16_OR_STRING_
SINGLE
(s) Start device of the own station where control data is
stored
Refer to the control data. Device name ANY16
*1
(d) Device of the own station, which turns on for one
scan upon completion of the instruction.
When the instruction completes with an error, (d)+1
also turns on.
Bit ANYBIT_ARRAY
(Number of elements: 2)
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(U) (s) (d)
EN ENO
dU
s