16.5 Executing the Protocols Registered for the Predefined Protocol Support Function
16.5 Executing the Protocols Registered for the
Predefined Protocol Support Function
GP.ECPRTCL
This instruction executes the communication protocol registered using the engineering tool.
Execution condition
Setting data
Description, range, data type
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
Ladder ST
ENO:=GP_ECPRTCL(EN,U,s1,s2,s3,d);
FBD/LD
Instruction Execution condition
GP.ECPRTCL
Operand Description Range Data type Data type (label)
(U) Start I/O number (first three digits in four-digit hexadecimal
representation) of own station or own node
00H to FEH 16-bit unsigned binary ANY16
(s1) Connection No. 1 to 16 16-bit unsigned binary ANY16
(s2) Number of protocols to be executed continuously 1 to 8 16-bit unsigned binary ANY16
(s3) Start device of the own station where control data is stored Refer to the control data. Device name ANY16
*1
(d) Device of the own station, which turns on for one scan
upon completion of the instruction.
When the instruction completes with an error, (d)+1 also
turns on.
Bit ANYBIT_ARRAY
(Number of elements: 2)
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(U) (s1) (s2) (s3) (d)
EN ENO
U
s1
d
s2
s3