1506
15  NETWORK COMMON INSTRUCTIONS
15.1  Link Dedicated Instructions
Writing data to the programmable controller (Q series-
compatible)
J(P).ZNWR
These instructions write data in units of words to a device in the programmable controller (MELSEC-A/QnA/Q/L series) of 
another station.
■Execution condition
Ladder ST
ENO:=J_ZNWR(EN,J,s1,s2,n,d1,d2);
ENO:=JP_ZNWR(EN,J,s1,s2,n,d1,d2);
FBD/LD
Instruction Execution condition
J.ZNWR
JP.ZNWR
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(J) (s1) (d1) (s2) (n) (d2)