7 APPLICATION INSTRUCTIONS
7.4 Structure Creation Instructions
Calling a subroutine program and turning the output off
FCALL(P)
These instructions perform non-execution processing of the subroutine program of the specified pointer.
■Execution condition
■Description, range, data type
*1 Cannot be specified in FBD/LD.
• In safety programs executed by the Safety CPU, only safety devices and safety labels of data types described in the table
can be used.
• [RnPCPU (redundant)] If these instructions are used in a program executed in both systems, there are restrictions on their operation in the standby system
when the redundant system is in backup mode. ( MELSEC iQ-R CPU Module User's Manual (Application))
Ladder ST
Not supported
FBD/LD
Instruction Execution condition
FCALL
FCALLP
Operand Description Range Data type Data type (label)
(P) Start pointer number of subroutine program Device name POINTER
(s1)(s5)
*1
Device number to be passed to the subroutine program as
an argument
-2147483648 to 2147483647 Bit/16-bit signed
binary/32-bit signed
binary
ANY
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)