36 COUNTER/TIMER FUNCTION BLOCKS
36.5 Pulse Timer
1989
36
36.5 Pulse Timer
TP(_E)
These function blocks keep the signal on for the specified period of time.
Setting data
Description, type, data type
Processing details
Operation processing
1. Output
When (s) turns on, (d1) turns on for the period of time set by (n). The time elapsed after (d1) turns on is set to (d2).
Use the long timer to count the elapsed time.
2. End of output
Once the elapsed time reaches the setting time, (d1) turns off.
If (s) is off after (d1) turns off, the elapsed time is reset.
Even when (s) turns off while (d1) is on, (d1) does not turn off.
3. Output time setting
The valid setting range of (n) is T#1ms to T#2147483ms. Note that the valid setting range will be as follows by changing the
timer limit setting using the engineering tool.
The value at the rising edge (off to on) of (d1) is used for the setting value of (n). When the (n) value is changed when (d1) is
on, the new value will be enabled at the next output start timing.
[RnPCPU (redundant)] If these function blocks are used in a program executed in both systems, they do not operate in the standby system when the
redundant system is in backup mode. ( MELSEC iQ-R CPU Module User's Manual (Application))
Ladder, FBD/LD Structured text
[Without EN/ENO] [With EN/ENO] [Without EN/ENO]
Instance name(IN:=s,PT:=n,Q:=d1,ET:=d2);
[With EN/ENO]
Instance name(EN:=en,ENO:=eno,IN:=s,PT:=n,Q:=d1,ET:=d2);
Argument Description Type Data type
EN Execution condition (TRUE: Executed, FALSE: Not executed) Input variable BOOL
s (IN) Start of output Input variable BOOL
n (PT) Output time setting value Input variable TIME
ENO Output status (TRUE: Normal, FALSE: Abnormal or operation stop) Output variable BOOL
d1 (Q) Output Output variable BOOL
d2 (ET) Elapsed time Output variable TIME
Minimum value Maximum value
Identical to the long timer setting value [ms] in the timer limit setting.
Note that if the long timer setting value is smaller than 1ms, the
minimum value will be 1ms.
The time satisfying the following condition is used.
Note that the maximum value is a value that can be included within the range of time
type because the output time setting value is of time type (32-bit value).
Output time setting value [ms] 2147483647 [ms] Long timer setting value in the
timer limit setting [ms]
[Example]
If the long timer setting value is 0.001ms: T#1ms to T#2147483ms
If the long timer setting value is 1000ms: T#1000ms to T#2147483000ms
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
s d1
d2n
EN ENO
d1
d2
s
n