Loading...
7 APPLICATION INSTRUCTIONS
7.3 Program Execution Control Instructions
551
7
Disabling/enabling the specified interrupt pointer
SIMASK
This instruction enables or disables the execution of the interrupt program with the specified interrupt pointer number.
Execution condition
Setting data
Description, range, data type
*1 Only labels assigned to the device (I) can be used.
Applicable devices
Ladder ST
ENO:=SIMASK(EN,I,s);
FBD/LD
Instruction Execution condition
SIMASK Every scan
Operand Description Range Data type Data type (label)
(I) Interrupt pointer number to be interrupt-enabled or -
disabled
I0 to I1023 Device name POINTER
*1
(s) Execution status of the specified interrupt pointer 0: Disabled
1: Enabled
16-bit unsigned binary ANY16
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
Operand Bit Word Double word Indirect
specification
Constant Others
(I)
X, Y, M, L,
SM, F, B, SB,
FX, FY
J\ T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
U\G, J\,
U3E\(H)G
Z LT, LST,
LC
LZ K, H E $
(I) 
(s) 
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(I) (s)
EN ENO
I
s

Table of Contents