EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Adding a Record to the Data Base

Mitsubishi Electric MELSEC iQ-R Series
2110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
956
7 APPLICATION INSTRUCTIONS
7.21 Database Access Instructions
Adding a record to the data base
DBINSERT(P)
These instructions add a record to the table of the database corresponding to the specified identification number.
Execution condition
Setting data
Descriptions, ranges, and data types
*1 The table and field names are case-sensitive.
*2 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
Ladder ST
ENO:=DBINSERT(EN,s1,s2,s3,s4,d1,d2);
ENO:=DBINSERTP(EN,s1,s2,s3,s4,d1,d2);
FBD/LD
Instruction Execution condition
DBINSERT
DBINSERTP
Operand Description Range Data type Data type (label)
(s1) Database identification number 1 to 4 16-bit signed binary ANY16
(s2) Start device for storing the database table names.
*1
Unicode string ANYSTRING_DOUBLE
(s3) Start device for storing the database field names.
*1
Word ANY16
*2
(s4) Start device for storing insertion data Word ANY16
*2
(d1) Completion device (start device that turns on one scan
upon completion of instruction)
(d1)+0: Completion signal
(d1)+1: Error completion signal
Bit ANYBIT_ARRAY
(Number of elements: 2)
(d2) Completion status
0000: Completed successfully
Other than 0000: Completed with an error (error code)
Word ANY16
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(s1) (s2) (s3) (s4) (d1) (d2)
EN ENO
s1
s2
d1
d2
s3
s4

Table of Contents