8 BUILT-IN ETHERNET FUNCTION INSTRUCTIONS
8.3 Predefined Protocol Support Function Instruction
1109
8
8.3 Predefined Protocol Support Function Instruction
Executing the registered protocols
SP.ECPRTCL
This instruction executes the protocol that has been set by the predefined protocol support function.
Execution condition
Setting data
Description, range, data type
Ladder ST
ENO:=SP_ECPRTCL(EN,U,s1,s2,s3,d);
FBD/LD
Instruction Execution condition
SP.ECPRTCL
Operand Description Range Data type Data type (label)
(U) Dummy String ANYSTRING_SINGLE
(s1) Connection number 1 to 16 16-bit unsigned binary ANY16
(s2) Number of protocols to be executed continuously 1 to 8 16-bit unsigned binary ANY16
(s3) Start device where control data is stored Refer to the control data. Word ANY16_ARRAY
(Number of elements: 2)
(d) Device that turns on for one scan upon completion of the
instruction
When the instruction completes with an error, (d)+1 also
turns on.
Bit ANYBIT_ARRAY
(Number of elements: 2)
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(U) (s1) (s2) (s3) (d)
EN ENO
U
s1
d
s2
s3