EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Converting LREAL to INT

Mitsubishi Electric MELSEC iQ-R Series
2110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1854
25 TYPE CONVERSION FUNCTIONS
25.44 Converting LREAL to INT
25.44 Converting LREAL to INT
LREAL_TO_INT(_E)
These functions convert a value from LREAL data type to INT data type.
Setting data
Description, type, data type
Processing details
Operation processing
These functions convert the value input to (s) from LREAL data type to INT data type, and output the converted value from
(d).
Input an LREAL data type value to (s).
After conversion, the first digit after the decimal point of the input value (LREAL data type) is rounded off.
Operation result
1. Function without EN/ENO
The operation processing is performed. The operation result is output from (d).
2. Function with EN/ENO
The execution conditions and operation results will be as follows.
*1 If the value FALSE is output from ENO, the output data from (d) will be undefined. Create a program so that the undefined value will not
be used in operations.
Ladder, FBD/LD Structured text
[Without EN/ENO] [With EN/ENO] [Without EN/ENO]
d:=LREAL_TO_INT(s);
[With EN/ENO]
d:=LREAL_TO_INT_E(EN,ENO,s);
Argument Description Type Data type
EN Execution condition (TRUE: Executed, FALSE: Not executed) Input variable BOOL
s (IN) Input Input variable LREAL
ENO Output status (TRUE: Normal, FALSE: Abnormal) Output variable BOOL
d Output Output variable INT
Execution condition Operation result
EN ENO (d)
TRUE (executed) TRUE Operation result output value
FALSE (not executed) FALSE
*1
Undefined value
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
sd
EN ENO
ds
(s)
(d)
12341234.0
INTLREAL

Table of Contents