920
7 APPLICATION INSTRUCTIONS
7.20 Data Processing Instructions
Checking the bit status in 32-bit binary data
DBON(P)
These instructions check whether (n) bit(s) of the specified device are on or off, and stores the result in the device specified by
(d).
Execution condition
Setting data
Description, range, data type
Applicable devices
*1 FX and FY cannot be used.
*2 T, ST, and C cannot be used.
The RnCPU and RnENCPU with firmware version "17" or later support these instructions. (Use an engineering tool with version "1.020W" or later.)
Ladder ST
ENO:=DBON(EN,s,n,d);
ENO:=DBONP(EN,s,n,d);
FBD/LD
Instruction Execution condition
DBON
DBONP
Operand Description Range Data type Data type (label)
(s) Device storing the data 32-bit signed binary ANY32
(d) Bit device for storing the result Bit ANY_BOOL
(n) Bit position to be checked 0 to 31 16-bit unsigned binary ANY16_U
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
Operand Bit Word Double word Indirect
specification
Constant Others
X, Y, M, L,
SM, F, B, SB,
FX, FY
J\ T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
U\G, J\,
U3E\(H)G
Z LT, LST,
LC
LZ K, H E $
(s)
*1
 
(d) 
*2
 
(n)
*1
 
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(s) (d) (n)