EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Page 1113

Mitsubishi Electric MELSEC iQ-R Series
2110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 BUILT-IN ETHERNET FUNCTION INSTRUCTIONS
8.3 Predefined Protocol Support Function Instruction
1111
8
+14 Collation match
Receive packet number
5
If receiving is included in the communication type of the protocol that has been
executed fifth, the receive packet number successful in collation match is stored. If
the communication type is "receive only", "0" is stored. If an error occurs during
execution of the fifth protocol, "0" is stored. If the number of protocols executed is
less than 5, "0" is stored.
0, 1 to 16 System
+15 Collation match
Receive packet number
6
If receiving is included in the communication type of the protocol that has been
executed sixth, the receive packet number successful in collation match is stored. If
the communication type is "receive only", "0" is stored. If an error occurs during
execution of the sixth protocol, "0" is stored. If the number of protocols executed is
less than 6, "0" is stored.
0, 1 to 16 System
+16 Collation match
Receive packet number
7
If receiving is included in the communication type of the protocol that has been
executed seventh, the receive packet number successful in collation match is stored.
If the communication type is "receive only", "0" is stored. If an error occurs during
execution of the seventh protocol, "0" is stored. If the number of protocols executed is
less than 7, "0" is stored.
0, 1 to 16 System
+17 Collation match
Receive packet number
8
If receiving is included in the communication type of the protocol that has been
executed eighth, the receive packet number successful in collation match is stored. If
the communication type is "receive only", "0" is stored. If an error occurs during
execution of the eighth protocol, "0" is stored. If the number of protocols executed is
less than 8, "0" is stored.
0, 1 to 16 System
Operand: (s3)
Device Item Description Setting range Set by

Table of Contents