3 MODULE DEDICATED INSTRUCTIONS
3.6 Serial Communication Instructions
141
3
Sending data by using user frames
Clearing receive data
Registering/canceling the programmable controller CPU monitoring
Initial setting
Registering user frames
Reading user frames
Switching the mode
Instruction symbol Processing details Reference
G.PRR Sends data with user frames according to the specification in the user frame specification area for
sending, through communication with the nonprocedural protocol.
Page 1699 G(P).PRR
GP.PRR
Instruction symbol Processing details Reference
ZP.CSET Clears the receive data area without stopping send processing by using the nonprocedural
protocol.
Page 1702 ZP.CSET
Instruction symbol Processing details Reference
ZP.CSET Registers programmable controller CPU monitoring to use the programmable controller CPU
monitoring function, or cancels programmable controller CPU monitoring.
Page 1705 ZP.CSET
Instruction symbol Processing details Reference
ZP.CSET Sets the unit (word/byte) of data to be sent or received. Page 1710 ZP.CSET
Instruction symbol Processing details Reference
G.PUTE Registers user frames. Page 1714 G(P).PUTE
GP.PUTE
Instruction symbol Processing details Reference
G.GETE Reads user frames. Page 1717 G(P).GETE
GP.GETE
Instruction symbol Processing details Reference
ZP.UINI Switches the serial communication module mode, transmission specifications, and own station
number.
Page 1721 ZP.UINI

Table of Contents