15 NETWORK COMMON INSTRUCTIONS
15.1 Link Dedicated Instructions
1467
15
The following figure shows the execution timing of the SREAD instruction.
Read processing is performed only once on the rising edge when the read command turns on.
When completed successfully
When completed with an error
100
100
END0END0END0END0END0
END0 END0END0END0END0
OFF
OFF OFF
OFF
ON
ON
OFF
OFF
ON
OFF
SREAD
Sequence scan
Start contact
CPU module on
the own station
CPU module on
the target station
Network
module
Network
module
Completion device
(d2)
Completion status
indication device
(d2)+1
Device for storing the
read device (d1)
Sequence scan
Device where the
read data is stored
(s2)
Channel n
1 scan
Read notification
device (d3)
1 scan
END0END0END0END0END0
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
SREAD
1 scan
Error code
Sequence scan
Start contact
CPU module on
the own station
Network
module
Completion device
(d2)
Completion status
indication device
(d2)+1
Completion status
(s1)+1
Channel n
Target station error