21 A/D CONVERSION INSTRUCTIONS
21.3 Restoring the User Range Setting Values
1761
21
For R60DA16-G
Operand: (s)
Device Item Description Setting range Set by
+0 System area 
+1 Completion status The instruction completion status is stored.
0: Completed successfully
Other than 0: Completed with an error (error code)
System
+2 Save data type setting 1 Used to store the set value that was set for Save data type
setting 1 (s)+2 in the G(P).OGLOAD instruction.
0H: User range setting 1 (current specification)
1H: User range setting 2 (voltage specification)
2H: User range setting 3 (voltage specification)
0000H to
AAAAH
System
+3 Save data type setting 2 Used to store the set value that was set for Save data type
setting 2 (s)+3 in the G(P).OGLOAD instruction.
0H: User range setting 1 (current specification)
1H: User range setting 2 (voltage specification)
2H: User range setting 3 (voltage specification)
0000H to
AAAAH
System
+4 CH1 Factory default setting offset value System
+5 CH1 Factory default setting gain value System
+6 CH2 Factory default setting offset value System
+7 CH2 Factory default setting gain value System
+8 CH3 Factory default setting offset value System
+9 CH3 Factory default setting gain value System
+10 CH4 Factory default setting offset value System
+11 CH4 Factory default setting gain value System
+12 CH5 Factory default setting offset value System
+13 CH5 Factory default setting gain value System
+14 CH6 Factory default setting offset value System
+15 CH6 Factory default setting gain value System
+16 CH7 Factory default setting offset value System
+17 CH7 Factory default setting gain value System
+18 CH8 Factory default setting offset value System
+19 CH8 Factory default setting gain value System
+20 CH9 Factory default setting offset value System
+21 CH9 Factory default setting gain value System
+22 CH10 Factory default setting offset value System
+23 CH10 Factory default setting gain value System
+24 CH11 Factory default setting offset value System
+25 CH11 Factory default setting gain value System
+26 CH12 Factory default setting offset value System
+27 CH12 Factory default setting gain value System
+28 CH13 Factory default setting offset value System
+29 CH13 Factory default setting gain value System
+30 CH14 Factory default setting offset value S
ystem
+31 CH14 Factory default setting gain value System
+32 CH15 Factory default setting offset value System
+33 CH15 Factory default setting gain value System
+34 CH16 Factory default setting offset value System
+35 CH16 Factory default setting gain value System
+36 CH1 User range setting offset value System
+37 CH1 User range setting gain value System
+38 CH2 User range setting offset value System
b15 b3b4b5b6b7b8b9b10b11b12b13b14 b2 b1 b0
CH8 CH7 CH6 CH5 CH4 CH3 CH2
CH1
b15 b3b4b5b6b7b8b9b10b11b12b13b14 b2 b1 b0
CH16 CH15 CH14 CH13 CH12 CH11 CH10 CH9