1848
25 TYPE CONVERSION FUNCTIONS
25.41 Converting REAL to DINT
Operation error
Error code
(SD0)
Description
3401H The single-precision real number input to (s) is out of the range, -2147483648 to 2147483647.
3402H An unusual number is input to (s).
The single-precision real number input to (s) is not within the following range:
-2
128
<(s)-2
-126
, 0, 2
-126
(s)<2
128
(E-3.40282347+38 to E-1.17549435-38, 0, E1.17549435-38 to E3.40282347+38)
The value set to a device or label is -0, a subnormal number, NaN (not a number), or .