30 SELECTION FUNCTIONS
30.3 Controlling the Upper/Lower Limit
1937
30
When (s1), (s2), or (s3) are of BOOL data type
When (s1), (s2), and (s3) are of REAL data type
When (s1), (s2), and (s3) are of LREAL data type
When (s1), (s2), and (s3) are of STRING data type
Error code
(SD0)
Description
3405H The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
Error code
(SD0)
Description
3402H The value input to (s1) is out of the following range:
-2
128
<(s1)-2
-126
, 0, 2
-126
(s1)<2
128
(E-3.40282347+38 to E-1.17549435-38, 0, E1.17549435-38 to E3.40282347+38)
The value input to (s1) is -0, a subnormal number, NaN (not a number), or .
The value input to (s2) is out of the following range:
-2
128
<(s2)-2
-126
, 0, 2
-126
(s2)<2
128
(E-3.40282347+38 to E-1.17549435-38, 0, E1.17549435-38 to E3.40282347+38)
The value input to (s2) is -0, a subnormal number, NaN (not a number), or .
The value input to (s3) is out of the following range:
-2
128
<(s3)-2
-126
, 0, 2
-126
(s3)<2
128
(E-3.40282347+38 to E-1.17549435-38, 0, E1.17549435-38 to E3.40282347+38)
The value input to (s3) is -0, a subnormal number, NaN (not a number), or .
3405H The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
Error code
(SD0)
Description
3402H The value input to (s1) is out of the following range:
-2
1024
<(s1)-2
-1022
, 0, 2
-1022
(s1)<2
1024
(E-1.7976931348623157+308 to E-2.2250738585072014-308, 0, E2.2250738585072014-308 to E1.7976931348623157+308)
The value input to (s1) is -0, a subnormal number, NaN (not a number), or .
The value input to (s2) is out of the following range:
-2
1024
<(s2)-2
-1022
, 0, 2
-1022
(s2)<2
1024
(E-1.7976931348623157+308 to E-2.2250738585072014-308, 0, E2.2250738585072014-308 to E1.7976931348623157+308)
The value input to (s2) is -0, a subnormal number, NaN (not a number), or .
The value input to (s3) is out of the following range:
-2
1024
<(s3)-2
-1022
, 0, 2
-1022
(s3)<2
1024
(E-1.7976931348623157+308 to E-2.2250738585072014-308, 0, E2.2250738585072014-308 to E1.7976931348623157+308)
The value input to (s3) is -0, a subnormal number, NaN (not a number), or .
3405H The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
Error code
(SD0)
Description
2820H There is no NULL code (00H) in the label or device area (between the specified device number and the last device number) specified by
(s1), (s2), or (s3).
3405H The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
The number of characters in the strings input to (s1), (s2), and (s3) exceeds 16383.
3406H The entire string cannot be stored in the label or device area (between the specified device number and the last device number) specified
by (d). (The number of required points is insufficient.)