196
5 SEQUENCE INSTRUCTIONS
5.3 Output Instructions
Processing details
This instruction turns off the annunciator specified by (d) when the execution command turns on.
The annunciator number (F number) turned off is deleted from the special register (SD64 to SD79), and the value in SD63
is decremented by one.
If the value in SD63 is 16, the corresponding annunciator number is deleted from SD64 to SD79 by the RST instruction. If
an annunciator with a number not registered in SD64 to SD79 has been turned on, the number is newly registered. If all
annunciator numbers in SD64 to SD79 are reset (turned off), the USER LED of the CPU module turns off.
Ex.
When the value in SD63 is 16 and there is an annunciator number that is not registered
Operation error
There is no operation error.
(1) Reset F90.
(2) The F number in SD66 is shifted to this area.
(3) New F number is stored.
SD63
SD64
SD65
SD66
SD78
SD79
SD63
SD64
SD65
SD77
SD78
SD79
16
233
90
700
145
1027
16
233
700
SD67
SD66
28
28
145
1027
(2)
(1)
(3)