7 APPLICATION INSTRUCTIONS
7.8 String Processing Instructions
649
7
Operation of when SM705 (Number of conversion digits selection) is on
Decimal ASCII data is stored right-justified in (d).
The following figures show an example of a value of (s) and a value stored in (d).
When the number of operation digits is less than the maximum number of digits (a sign + 10 digits), 00H is stored in the end
of the string regardless of the status (on/off) of SM701 (Number of output characters selection). If the end of the string is the
lower byte, 00H is also stored in the upper byte.
When the number of operation digits is equal to the maximum number of digits (a sign + 10 digits), 00H is stored in the
upper byte of (d)+5 if SM701 is off. 20H (space) is stored in the upper byte of (d)+5 if SM701 is on.
Operation error
There is no operation error.
Value of (s) Data of (d) to (d)+2 Value of (s) Data of (d) to (d)+2
•0
Positive value (1
digit in numeric
part)
The upper byte of (d) is filled with 00H.
(d)+1 and later remain unchanged.
Positive value (2
digits in numeric
part)
Negative value (1
digit in numeric
part)
(d)+1 is filled with 00H.
(d)+2 and later remain unchanged.
Positive value (9
digits in numeric
part)
Negative value (8
digits in numeric
part)
The upper byte of (d)+4 is filled with 00H.
(d)+5 and later remain unchanged.
Positive value (10
digits in numeric
part)
Negative value (9
digits in numeric
part)
(d)+5 is filled with 00H.
Negative value (10
digits in numeric
part)
00H is stored in the upper byte (1) of (d)+5 when
SM701 (Number of output characters selection) is
off, and 20H (space) is stored when it is on.
ASCII 10
9
: Billions place of ASCII code
ASCII 10
8
: Hundred-millions place of ASCII code
ASCII 10
1
: Tens place of ASCII code
ASCII 10
0
: Ones place of ASCII code
(d)+1
(d)+2
(d)+3
(d)+4
(d)+5
(d)
b15 b0 b7b8
00H ASCII 10
0
(d)+1
(d)+2
(d)+3
(d)
b15 b0 b7b8
ASCII 10
1
/ 2DH (-)
00H
ASCII 10
0
(d)+4
(d)+5
(d)+1
(d)+2
(d)+3
(d)+4
(d)+5
(d)
b15 b0 b7b8
ASCII 10
7
ASCII 10
5
ASCII 10
8
/ 2DH (-)
ASCII 10
6
ASCII 10
3
ASCII 10
4
ASCII 10
1
ASCII 10
2
00H ASCII 10
0
(d)+1
(d)+2
(d)+3
(d)
b15 b0 b7b8
ASCII 10
7
ASCII 10
5
ASCII 10
9
/ 2DH (-)
ASCII 10
8
ASCII 10
6
ASCII 10
3
ASCII 10
4
ASCII 10
1
ASCII 10
2
00H
ASCII 10
0
(d)+4
(d)+5
(d)+1
(d)+2
(d)+3
(d)
b15 b0 b7b8
ASCII 10
9
ASCII 10
7
ASCII 10
5
2DH (-)
ASCII 10
8
ASCII 10
6
ASCII 10
3
ASCII 10
4
ASCII 10
1
ASCII 10
2
00H / 20H ASCII 10
0
(1)
(d)+4
(d)+5