EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Page 72

Mitsubishi Electric MELSEC iQ-R Series
2110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
2 CPU MODULE INSTRUCTIONS
2.1 Sequence Instructions
Output instructions
Out (excluding the timer, counter, and annunciator)
Timer, long timer
Counter, long counter
Annunciator
Setting devices (excluding annunciator)
Resetting devices (excluding annunciator)
Setting/resetting annunciator
Rising/falling edge output
Inverting the bit device output
Converting the direct access output into a pulse
Instruction symbol Processing details Reference
OUT Outputs the operation result to the specified device. Page 175 OUT
Instruction symbol Processing details Reference
OUT T Starts time measurement when the operation result up to the OUT instruction is on. When time is
up, the normally open contact turns on (continuity state) and the normally closed contact turns off
(non-continuity state).
OUT T: Low-speed timer instruction
OUTH T: High-speed timer instruction
OUT ST: Low-speed retentive timer instruction
OUTH ST: High-speed retentive timer instruction
OUT LT: Low-speed long timer instruction
OUT LST: Low-speed long retentive timer instruction
Page 177 OUT T,
OUTH T, OUT ST,
OUTH ST
OUTH T
OUT ST
OUTH ST
OUT LT Page 181 OUT LT,
OUT LST
OUT LST
Instruction symbol Processing details Reference
OUT C Increments the current counter value (count value) by one when the operation result up to the OUT
instruction turns on. When the count value reaches the set value, the normally open contact of the
counter turns on (continuity state) and the normally closed contact turns off (non-continuity state).
OUT C: Counter
OUT LC: Long counter
Page 184 OUT C
OUT LC Page 186 OUT LC
Instruction symbol Processing details Reference
OUT F Outputs the operation result up to the OUT F instruction to the specified annunciator. Page 188 OUT F
Instruction symbol Processing details Reference
SET Turns on the specified bit. Page 189 SET
Instruction symbol Processing details Reference
RST Turns off the specified device. For the timer and counter, the instruction clears the current value to
0 and turns off the contact or coil.
Page 191 RST
Instruction symbol Processing details Reference
SET F Turns on the specified annunciator. Page 193 SET F
RST F Turns off the specified annunciator. Page 195 RST F
Instruction symbol Processing details Reference
PLS Turns on the specified device for one scan on the rising edge (off to on) of the execution command. Page 197 PLS
PLF Turns on the specified device for one scan on the falling edge (on to off) of the execution
command.
Page 199 PLF
Instruction symbol Processing details Reference
FF Inverts the status of the specified device. Page 201 FF
Instruction symbol Processing details Reference
DELTA Converts the specified direct access output (DY) into pulse output. Page 203 DELTA(P)
DELTAP

Table of Contents

Other manuals for Mitsubishi Electric MELSEC iQ-R Series

Related product manuals