7 APPLICATION INSTRUCTIONS
7.9 Real Number Instructions
763
7
If 2BH(+) is specified for the sign or the sign is omitted in decimal point format, the converted single-precision real number
is treated as a positive value. If 2DH(-) is specified for the sign, it is treated as a negative value.
If 20H (space) or 30H (0) exists between digits excluding the first 0 in the character string in the device specified by (s), the
instruction performs conversion by ignoring 20H and 30H.
Exponential format
When the character string in the device specified by (s) is in exponential format, conversion is performed as shown below.
The character string in the device specified by (s) to be converted to a single-precision real number is converted by
assuming that the six digits excluding the sign, decimal point, and exponent are effective and the seventh and subsequent
digits are discarded.
(1) Ignored.
(2) Single-precision real number
(1) Single-precision real number
(1) Rounded down.
(2) Single-precision real number
(s)
(s)+1
(s)+2
(s)+3
(s)+4
b15 b0 b7b8
00H
(d)(d)+1
31H (1)
32H (2)
2DH (-)
30H (0)
2EH (.)
31H (1) 33H (3)
1
.
2
3 10-
1-.231
(1)
(2)
20H (space)
(d)(d)+1
2EH (.)
32H (2)
31H (1)
2DH (-)
33H (3)
2BH (+)
30H (0)
30H (0)
45H (E)
31H (1)
-
021-.3 11+
(s)
(s)+1
(s)+2
(s)+3
(s)+4
(s)+5
(s)+6
b15 b0 b7b8
00H
1 . 3 2 0 1 E + 1 0
31H (1)
E0
(1)
20H (space)
(d)(d)+1
2EH (.)
35H (5)
33H (3)
31H (1)
45H (E)
-
01- .35 E-234
(s)
(s)+1
(s)+2
(s)+3
(s)+4
(s)+5
(s)+6
(s)+7
b15 b0 b7b8
30H (0)
00H
- 53.1 0 3 4 1 2 E - 0 2
2DH (-)
33H (3)
30H (0)
34H (4)
32H (2)
2DH (-)
32H (2)
31H (1)
(2)
(1)
20H (space)