776
7 APPLICATION INSTRUCTIONS
7.9 Real Number Instructions
• These instructions calculate the tangent of the angle specified by (s), and store the operation result in the device specified
by (d).
• Set the angle data in radians (angle180).
• If the operation result is -0 or an underflow occurs, the operation result turns out to 0.
• When an input value is set using the engineering tool, a rounding error may occur. Refer to the following for the precautions
on setting input values using the engineering tool.
Page 49 Precautions
If the angle specified by (s) is /2 radian or (3/2) radian, no operation error will be issued because of the truncation error in
the radian value.
For the angleradian conversion, refer to the RAD(P) and DEG(P) instructions.
Page 807 RAD(P)
Page 809 DEG(P)
Error code
(SD0)
Description
3402H The value input to (s) is -0, a subnormal number, NaN (not a number), or .
(s)+1 (s) (d)+1 (d)
TAN ( )