832
7 APPLICATION INSTRUCTIONS
7.9 Real Number Instructions
Processing details
These instructions raises the single-precision real number specified by (s1) to the power of the single-precision real number
specified by (s2), and store the operation result in the device specified by (d).
The values that can be specified by (s1) and (s2) and the value that can be stored are 0, 2
-126
|setting value (stored
value)|<2
128
.
If the operation result is -0 or an underflow occurs, the operation result turns out to 0.
When an input value is set using the engineering tool, a rounding error may occur. Refer to the following for the precautions
on setting input values using the engineering tool.
Page 49 Precautions
Operation error
Error code
(SD0)
Description
3402H The value input to (s1) or (s2) is -0, a subnormal number, NaN (not a number), or .
(s2)+1 (s2)
(s1)+1 (s1)
(s1)+1 (s1)
(d)+1 (d)
Single-precision
real number
Single-precision
real number
Base number
Exponent
to the th power
(s2)+1 (s2)