992
7 APPLICATION INSTRUCTIONS
7.22 File Register Operation Instructions
Processing details
These instructions switch the block number of the file register used in the program to that stored in the device specified by
(s). After the block number is changed, all file registers processed by the sequence program are those linked to the new
block number.
Precautions
For the restrictions of the file register, refer to the following.
Page 65 Restrictions on using file registers
Operation error
Error code
(SD0)
Description
2820H The specified file register does not exist.
3405H The block number in the device specified by (s) does not exist.
R0
R32767 R32767
R0
R32767
R0
(s)



Execution of the instruction
Block number setting
Block No.1 Block No.'n'Block No.0
(Currently being
used.)
(Used after the
execution of the
RSET instruction.)