EasyManua.ls Logo

NETGEAR M4200

NETGEAR M4200
688 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Link Dependency
660
Managed Switches
CLI: Create a Link State Group
1. Create a link state group with group number 1.
2. Configure port 1/0/1 as an upstream link.
3. Configure port 1/0/5 as a downstream link.
4. Display the status of the link state group with group number 1.
Web Interface: Create a Link State Group
1. Configure the action for link state group with group number 1.
a. Select System > Link Dependency > Link Dependency Group Configuration.
A screen similar to the following displays.
(Netgear Switch) (Config)#link state group 1 action down
(Netgear Switch) (Config)#interface 1/0/1
(Netgear Switch) (Interface 1/0/1)#link state group 1 upstream
(Netgear Switch) (Interface 1/0/1)#interface 1/0/5
(Netgear Switch) (Interface 1/0/5)#link state group 1 downstream
(Netgear Switch) (Interface 1/0/5)#exit
(Netgear Switch) #show link state group 1
GroupId Downstream Interfaces Upstream Interfaces Link Action Group State
------- ---------------------- -------------------- ------------ -----------
1 1/0/5 1/0/1 Link Down Up