Diagnosing Switch Problems sFlow Overview
OmniSwitch AOS Release 7 Network Configuration Guide June 2013 page 32-7
sFlow Overview
The following sections detail the specifications, defaults, and quick set up steps for the sFlow feature.
Detailed procedures are found in “sFlow” on page 32-29.
sFlow Specifications
sFlow Defaults
The following table shows sFlow default values:
sFlow Defaults
RFCs Supported 3176 - sFlow
Management Information Base
Platforms Supported OmniSwitch 10K, 6900
Receiver/Sampler/Polling Instances 2
Sampling length of packet
type of frame
source and destination MACs
source and destination VLANs
source and destination priorities
source and destination IP addressessource and
destination ports
tcp flags and tos
Polling In octets
Out octets
Number of Rx Unicast packets
Number of Tx Unicast packets
Number of Rx Multicast packets
Number of Tx Multicast packets
Number of Rx Broadcast packets
Number of Tx Broadcast packets
In Errors
Out Errors
Agent IP Address Configurable using sflow agent ip command.
Parameter Description CLI Command Default Value/Comments
Receiver Name sflow receiver Empty
Receiver Timeout Value sflow receiver No Timeout
Receiver IP Address sflow receiver 0.0.0.0
Receiver Data File Size sflow receiver 1400 Bytes
Receiver Version Number sflow receiver 5
Receiver Destination Port sflow receiver 6343
Sampler Rate sflow sampler 0