Switch Health Overview Diagnosing Switch Problems
page 32-14 OmniSwitch AOS Release 7 Network Configuration Guide June 2013
Switch Health Defaults
The following table shows Switch Health default values.
Global Switch Health Defaults
Quick Steps for Configuring Switch Health
1 Display the health threshold limits, health sampling interval settings, and/or health statistics for the
switch, depending on the parameters you wish to modify. (For best results, note the default settings for
future reference.) For example:
-> show health configuration
The default settings for the command you entered is displayed. For example:
Rx Threshold = 80
TxRx Threshold = 80
Memory Threshold = 80
CPU Threshold = 80
Sampling Interval (Secs) = 10
2 Enter the appropriate command to change the required health threshold or health sampling interval
parameter settings or reset all health statistics for the switch. For example:
-> health threshold memory 85
Note. Optional. To verify the Switch Health configuration, enter show health configuration, followed by
the parameter you modified (like the memory percent). The display is similar to the one shown below:
Memory Threshold = 85
For more information about this command, see “Displaying Health Threshold Limits” on page 32-44 or
the “Health Monitoring Commands” chapter in the OmniSwitch CLI Reference Guide.
Parameter Description CLI Command Default Value/Comments
Resource Threshold Limit Configuration health threshold 80 percent
Sampling Interval Configuration health interval 5 seconds
Switch Temperature health threshold 60 degrees Celsius