"B" Group: Fine Tuning Functions Section 3-6
The inverter mode cannot be changed just setting b171. After setting b171, be
sure to execute initialization to activate new mode.
Actual inverter mode can be monitored with d060.
Once high frequency mode is set, initialization can be done just by setting
b084, b085, b094 and setting b180, it is not needed to set b171 .
Main differences between high frequency and std. mode are as follows.
"B" Function Run
Mode
Edit
Defaults
Func.
Code
Name Description EU Units
b171 Inverter mode selection Three option codes:
00 No function
01 Std. IM (Induction Motor)
02 High frequency IM
03 PM (Permanent Magnet Motor)
8 00
Function High frequency
mode
Standard mode Permanent Magnet
Rating HD HD ND HD
Max. freq. (A004) 1000Hz 400Hz 400Hz 400Hz
Start freq. (b082) 0.10 to 100.0 (Hz) 0.10 to 9.99 (Hz) 0.10 to 9.99 (Hz) 0.10 to 9.99 (Hz)
Carrier freq. (b083) 2.0 to 10.0 (kHz) 2.0 to 15.0 (kHz) 2.0 to 10.0 (kHz) 2.0 to 15.0 (kHz)
V/f characteristic curve
(A044)
00: Const. torque
01: Reduced torque
02:Free V/f
00: Const. torque
01: Reduced torque
02:Free V/f
03:SLV
00: Const. torque
01: Reduced torque
02: Free V/f
Not available
HD mode
b049: 00
d060: 1-C
ND mode
b049: 01
d060: 1-v
High freq. mode
d060: H-1
Normal mode (400 Hz)
HD mode
High freq. (1000 Hz)
Permanent magnet
mode
d060: P
Permanent magnet mode
b171 = 01
+ init.
b049 = 01
b049 = 00
b171 = 02
b171 = 02
+ init.
+ init.
b171 = 03
+ init.
b171 = 03
+ init.
b171 = 03
+ init.
ND mode
b171 = 01
+ init.

Table of Contents

Other manuals for Omron MX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 and is the answer not in the manual?

Omron MX2 Specifications

General IconGeneral
ModelMX2
CategoryInverter
Enclosure RatingIP20
Control MethodV/f control, Sensorless vector control
Frequency Range0.1 to 400 Hz
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat, Short circuit
CommunicationModbus RTU
Ambient Temperature-10 to 50 °C (without freezing or condensation)
Overload Capacity150% for 60 seconds
Cooling MethodFan Cooled
Humidity5 to 95% RH (without condensation)
AltitudeUp to 1000m without derating
Voltage200-240 VAC, 380-480 VAC
Braking UnitBuilt-in (for certain models), Optional External