298
ModBus Data Listing Section B-4
1427h Low current detection level C039 R/W 0 to 2000 0.1 [%]
1428h Overload signal output mode C040 R/W 00 (output during acceleration/decelera-
tion and constant-speed operation), 01
(output only during constant-speed
operation)
–
1429h Overload warning level C041 R/W 0 to 2000 0.1 [%]
142Ah Frequency arrival setting for accel. C042 (high) R/W 0 to 40000 0.01 [Hz]
142Bh C042 (low) R/W
142Ch Frequency arrival setting for decel. C043 (high) R/W 0 to 40000 0.01 [Hz]
142Dh C043 (low) R/W
142Eh PID deviation level C044 R/W 0 to 1000 0.1 [%]
142Fh Frequency arrival setting 2 for
accel.
C045 (high) R/W 0 to 40000 0.01 [Hz]
1430h C045 (low) R/W
1431h Frequency arrival setting 2 for
decel.
C046 (high) R/W 0 to 40000 0.01 [Hz]
1432h C046 (low) R/W
1433h Pulse train input scale conver-
sion for EO output
C047 R/W 0.01 - 99.99 –
1434h to
1437h
(Reserved) – – – –
1438h Maximum PID feedback data C052 R/W 0 to 1000 0.1 [%]
1439h Minimum PID feedback data C053 R/W 0 to 1000 0.1 [%]
143Ah Over-torque/under-torqueselection C054 R/W 0(Over torque)/1(under torque) –
143Bh Over-torque (forward-driving)
level setting
C055 R/W 0 to 200 1 [%]
143Ch Over-torque (reverse regenerat-
ing) level setting
C056 R/W 0 to 200 1 [%]
143Dh Over-torque (reverse driving)
level setting
C057 R/W 0 to 200 1 [%]
143Eh Over-torque (forward regenerat-
ing) level setting
C058 R/W 0 to 200 1 [%]
143Fh Signal output mode of Over/
under torque
C059 R/W 00 (output during acceleration/decelera-
tion and constant-speed operation),
01 (output only during constant-speed
operation)
–
1440h (Reserved) – – – –
1441h Electronic thermal warning level C061 R/W 0 to 100 1 [%]
1442h (Reserved) – – –
1443h Zero speed detection level C063 R/W 0 to 10000 0.01 [Hz]
1444h Heat sink overheat warning level C064 R/W 0 to 110 1 [?]
1445h to
144Ah
(Reserved) – – – –
144Bh Communication speed C071 R/W 03 (2400bps), 04 (4800bps),
05 (9600bps), 06 (19.2kbps),
07 (38.4kbps), 08 (57.6kbps),
09 (76.8kbps), 10 (115.2kbps)
–
144Ch Modbus address C072 R/W 1. to 247. –
144Dh (Reserved) – – – –
144Eh Communication parity C074 R/W 00 (no parity), 01 (even parity),
02 (odd parity)
–
144Fh Communication stop bit C075 R/W 1 (1 bit), 2 (2 bits) –
1450h Selection of the operation after
communication error
C076 R/W 0 (tripping), 1 (tripping after decelerating and
stopping the motor), 2 (ignoring errors),
3 (stopping the motor after free-running),
4 (decelerating and stopping the motor)
–
1451h Communication timeout limit C077 R/W 0 to 9999 0.01 [sec.]
1452h Communication wait time C078 R/W 0 to 1000 1 [msec.]
1453h to
1454h
(Reserved) – – – –
1455h [O] input span calibration C081 R/W 0 to 2000 0.1
1456h [OI] input span calibration C082 R/W 0 to 2000 0.1
1457h to
1458h
(Reserved) – – – –
1459h Thermistor input tuning C085 R/W 0 to 2000 0.1
145Ah to
145Eh
(Reserved) – – – –
Register
No.
Function name Function
code
R/W Monitoring and setting items Data
resolution