EasyManuals Logo

Omron MX2 User Manual

Omron MX2
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #342 background imageLoading...
Page #342 background image
320
Parameter Settings for Keypad Entry Section C-2
C056 Over/under-torque level
(Reverse regen. mode)
100.
C057 Over/under-torque level
(Reverse powering mode)
100.
C058 Over/under-torque level
(Forward regen. mode)
100.
C059 Signal output mode of Over/under
torque
01
C061 Electronic thermal warning level 90.
C063 Zero speed detection level 0.00
C064 Heat sink overheat warning 100.
C071 Communication speed 05
C072 Modbus address 1.
C074 Communication parity 00
C075 Communication stop bit 1
C076 Communication error select 02
C077 Communication error time-out 0.00
C078 Communication wait time 0.
C081 [O] input span calibration 100.0
C082 [OI] input span calibration 100.0
C085 Thermistor input (PTC) span
calibration
100.
C091 Debug mode enable 00
C096 Communication selection 00.
C098 EzCOM start adr. of master 1.
C099 EzCOM end adr. of master 1.
C100 EzCOM starting trigger 00
C101 Up/Down memory mode selection 00
C102 Reset selection 00
C103 Restart mode after reset 00
C104 UP/DWN clear mode 00
C105 EO gain adjustment 100.
C106 AM gain adjustment 100.
C109 AM bias adjustment 0.
C111 Overload warning level 2 Rated current
C130 Output [11] on-delay time 0.0
C131 Output [11] off-delay time 0.0
C132 Output [12] on-delay time 0.0
C133 Output [12] off-delay time 0.0
C140 Relay output on-delay time 0.0
C141 Relay output off-delay time 00
C142 Logic output 1 operand A 00
C143 Logic output 1 operand B 00
C144 Logic output 1 operator 00
C145 Logic output 2 operand A 00
C146 Logic output 2 operand B 00
C147 Logic output 2 operator 00
C148 Logic output 3 operand A 00
C149 Logic output 3 operand B 00
C150 Logic output 3 operator 00
C160 Input [1] response time 1.
"C" Group Parameters Default Setting B031=10 User
Setting
Func.
Code
Name (EU)

Table of Contents

Other manuals for Omron MX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 and is the answer not in the manual?

Omron MX2 Specifications

General IconGeneral
ModelMX2
CategoryInverter
Enclosure RatingIP20
Control MethodV/f control, Sensorless vector control
Frequency Range0.1 to 400 Hz
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat, Short circuit
CommunicationModbus RTU
Ambient Temperature-10 to 50 °C (without freezing or condensation)
Overload Capacity150% for 60 seconds
Cooling MethodFan Cooled
Humidity5 to 95% RH (without condensation)
AltitudeUp to 1000m without derating
Voltage200-240 VAC, 380-480 VAC
Braking UnitBuilt-in (for certain models), Optional External