– 123 – NWA-008845-001 Rev.5.0
32ch1002.fm
DESCRIPTION DATA
Assign MF Receiver sensitive level.
(1)
(2)
Y=1
1: MF Receiver Sensitive level
00-14: –21 dBm- –35 dBm
15 : –36 dBm (–1 dBm increments)
Assign MF Receiver to each circuit number (0-
3) of the MF Receiver Trunk.
(1)
(2)
Y=2
0-3 : AP No. NOTE
3 : All circuits assigned as Receiver
NOTE: AP numbers 0-3 correspond to the AP
numbers assigned by CM05 (04-15,
20-31):
CM31 Y=2
CM05 Y=0
AP Number 0: AP Number X
AP Number 1: AP Number Y
AP Number 2: AP Number Z
AP Number 3: AP Number W
(X<Y<Z<W)
Assign supervisory timer of interdigit pause on
incoming signal.
(1)
(2)
Y=B
05: Supervisory Timer of Interdigit Pause
on Incoming Signal
NONE : 24 seconds
01-31 : 1-31 seconds
Assign Busy/Idle information not to be sent to
T1 network.
(1)
(2)
Y=48 Busy/Idle Sending to T1 Network
00-63: Trunk Route No.
0: Not available
A
CM31
INITIAL
INITIAL
CM35
END
AUTOMATIC NUMBER IDENTIFICATION (ANI)

Table of Contents