– 188 – NWA-008845-001 Rev.5.0
32ch1003.fm
To provide Calling Number and Calling Name Display on D
term
/ATTCON LCD simultaneously, do the
following programming:
[Series 3800 software required]
DESCRIPTION DATA
Assign Service Restriction Class A for Caller
ID Display on the LCD of D
term
to the required
stations.
(1)
(2)
Y=02
X-XXXXXXXX: My Line No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Specify the displaying pattern of Caller ID on
the LCD of D
term
before answering or after
answering a trunk call.
(1)
(2)
Y=400
00-15: Service Restriction Class A as-
signed by CM12 Y=02
0: To display calling number on upper line
of LCD, calling name on middle line of
LCD
1: To display calling name on upper line of
LCD, calling number on middle line of
LCD
Allow Calling Name Display for incoming
trunk calls in Service Restriction Class A as-
signed by CM12 Y=02.
(1)
(2)
Y=136
00-15: Service Restriction Class A as-
signed by CM12 Y=02
0 : Calling Number Display
1 : Calling Name Display
Allow blinking LCD for caller ID Display on
each D
term
.
(1)
(2)
Y=215
00-15: Service Restriction Class A as-
signed by CM12 Y=02
0 : Restricted
1 : Allow
Specify the displaying pattern of Caller ID on
the LCD of ATTCON before answering or
after answering a trunk call.
(1)
(2)
Y=34
0-7: ATTCON No.
0: To display calling number on upper line
of LCD, calling name on middle line of
LCD
Specify the information to display on the
middle line of the D
term
/ATTCON LCD when
forwarding a trunk call to the D
term
/ATTCON
by Call Forwarding-All Calls/No Answer/
Busy Line/Not Available.
(1)
(2)
563
0 : Forwarding station name
1 : Caller ID
(Calling number/Calling name)