– 200 – NWA-008845-001 Rev.5.0
32ch1004.fm
DESCRIPTION DATA
Specify the operation for calling number auto-
matically storing per station when the number
of calling number is over the maximum.
[Series 3900 software required]
NOTE: This command is effective only for
automatically storing calling num-
ber of trunk calls.
(1)
(2)
589
0 : To delete the oldest calling number
and store the new calling number
1 : Not stored the new calling number
Provide each D
term
with Message Waiting.
(1)
(2)
Y=03
X-XXXXXXXX: Station No.
0: To provide
Assign Service Restriction Class A for CID
Call Back to the required stations.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow CID Call Back in Service Restriction
Class A assigned by CM12 Y=02.
(1)
(2)
Y=126
00-15: Service Restriction Class A as-
signed by CM12 Y=02
0: Allow
Provide the trunk route with the CID Call
Back.
(1)
(2)
Y=150
00-63: Trunk Route No.
0: To provide
Assign the trunk access code for CID Call
Back.
This trunk access code will be saved and sent
with the calling number.
(1)
(2)
Y=44
00-63: Trunk Route No.
0-9/00-99: Trunk Access Code
Assign a Numbering Plan Group number to
each tenant.
(1)
(2)
00-63: Tenant No.
710-713: Numbering Plan Group 0-3
Assign the access code for Message Waiting/
Message Reminder Search/Retrieve/Set/
Cancel.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A146: Message Waiting Search
A147: Message Waiting Retrieve
A148: Message Reminder Set
A149: Message Reminder Cancel
A
CM08
CM13
CM12
CM15
CM35
CM29
CM20
B
JUNE/01/2007
CID CALL BACK