– 266 – NWA-008845-001 Rev.5.0
32ch1005.fm
HARDWARE REQUIRED
D
term
with LCD and Soft Key, and DLC card
DESCRIPTION DATA
Assign the number to be dialed to each Memo-
ry Slot number, if required. The numbers to be
called are usually set from individual stations
by their station users.
(1)
(2)
Y=0
X YY Z
X : 0-9: 1000-Slot Memory Block No.
YY: 00-99: 10-Slot Memory Block No.
Z : 0-9: Memory Parcel No.
Stored No.:
Outgoing Access Code (Maximum 4 digits)
+ + Called Party No. (Maximum 26
digits)
To set a pause into the Stored No., enter
“C” (Fixed Pause=1.5 seconds) or
“D” (Programmable Pause specified by
CM41 Y=0>38) after desired digits.
NONE : No data
Assign the station name to be displayed to each
Memory Slot number, by character codes or
character.
(1)
(2)
Y=1
X YY Z
X : 0-9: 1000-Slot Memory Block No.
YY: 00-99: 10-Slot Memory Block No.
Z : 0-9: Memory Parcel No.
XX...XX: Station Name Character Code
(Maximum 32 digits, 16 charac-
ters)
NONE : No data
See APPENDIX B: Character Code Table.
Page B2
(1)
(2)
Y=2
X YY Z
X : 0-9: 1000-Slot Memory Block No.
YY: 00-99: 10-Slot Memory Block No.
Z : 0-9: Memory Parcel No.
XX...XX: Station Name Character by
MAT/CAT (Maximum 16
characters)
NONE : No data
C
CM74
,
END