– 474 – NWA-008845-001 Rev.5.0
32ch1008.fm
DESCRIPTION DATA
Specify the time display for Message Remind-
er on D
term
with LCD.
(1)
(2)
280
0: 24-Hour
1: 12-Hour
Specify Message Waiting Lamp indication on
the station to which Message Reminder is set.
(1)
(2)
294
0 : Flashing (60 IPM)
1 : Steady Lighting
Provide Message Reminder for each station. •
(1)
(2)
Y=03
X-XXXXXXXX: Station No.
0 : To provide (for stations with MW
lamp or D
term
with LCD)
1 : Not Provided
Assign Service Restriction Class A for Mes-
sage Reminder to required stations.
•
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow Message Reminder in Service Restric-
tion Class A assigned by CM12 Y=02.
•
•
(1)
(2)
Y=47 Message Reminder (Setting Side)
Y=48 Message Reminder (Set Side)
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
Assign the access code for Message Reminder
Search, Retrieve, Set, or Cancel.
•
(1)
(2)
Y=0-3 Numbering Plan Group (0-3)
X-XXXX: Access Code (*9, #9)
A146: Message Reminder Search
A147: Message Reminder Retrieve
A148: Message Reminder Set
A149: Message Reminder Cancel
Assign the MSG key to each D
term
.•
(1)
(2)
Y=00
My Line No. + + Key No.
F0A46: Message Reminder Search
F1005 : Message Reminder Retrieve
A
CM08
CM13
CM12
CM15
CM20
CM90
,
END
NOVEMBER/15/2006