EasyManua.ls Logo

Philips Sopho 2000 IPS - Page 514

Philips Sopho 2000 IPS
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 496 – NWA-008845-001 Rev.5.0
32ch1008.fm
To provide Mobility Access (MA), do the following programming.
DESCRIPTION DATA
Assign Service Restriction Class A to each sta-
tion.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow Mobility Access mode in Service Re-
striction Class A assigned by CM12 Y=02.
NOTE: This command is set to the Mobility
Access station.
(1)
(2)
Y=216
00-15: Service Restriction Class A as-
signed by CM12 Y=02
0 : Restricted
1 : Allow
Assign the following Mobility Access function
to each DID Number.
- For MA termination : 1 (2nd data=0)
- For MA mode setting: 1 (2nd data=1)
- For MA mode cancel: 1 (2nd data=2)
- For MA station : Same number of MA
station (2nd data=7)
(1)
(2)
Y=41
000-999: Number Conversion Block No.
assigned by CM76 Y=00/90
0 : To use Mobility Access termination
1 : To set Mobility Access Mode
2 : To cancel Mobility Access Mode
7 : Not used Mobility Access function
Assign a trunk access code for call forwarding
in Mobility Access mode.
(1)
(2)
Y=10
00-63: Tenant No.
X-XXXX: Trunk Access Code (1-4 digits)
NONE : No data
START
CM12
CM15
CM76
CM64
END