EasyManua.ls Logo

Philips Sopho 2000 IPS - Page 767

Philips Sopho 2000 IPS
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 749 – NWA-008845-001 Rev.5.0
32ch1011.fm
DESCRIPTION DATA
Assign the access code for MW lamp set/reset
from a VMS station port.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access code
A040: Set
A041: Reset
Assign the access code to retrieve a message
from the VMS and search Message Reminder/
Message Waiting.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access code
A146: Search
A147: Retrieve
Assign the access code to be sent out to a VMS
after/before a Mail Box number, if required.
NOTE 1: “C” or “D” should not be assigned
as the first digit of an access code, to
insert prepause timing. Prepause
timing is assigned by CM41
Y=0>44.
NOTE 2: If “C” is inserted in the access code,
it can be used as a pause (1.5 sec-
onds). To provide a programmable
pause, insert “D” instead of “C”
(Programmable Pause: CM41
Y=0>38).
(1)
(2)
Y=00
3: Access Code to be sent out before a Mail
Box No.
NOTE 1
4: Access Code to be sent out after a Mail
Box No.
XX-XXXX: Access code to be sent out to a
VMS
X: 0-9, A (*), B (#), C/D (Pause)
NOTE 2
NONE : Not sent out
Specify the prepause timing, DTMF signal
width, and Inter-digital pause for VMS.
(1)
(2)
Y=0
44: Prepause Timing
00-12, 13: 0-12, 0.5 seconds
If no data is set, the default setting is 1 second.
Specify the DTMF signal width for VMS.
(1)
(2)
Y=0
48
01: 64 ms.
02: 128 ms.
If no data is set, the default setting is 128 ms.
Specify the DTMF inter-digital pause for
VMS.
(1)
(2)
Y=0
49
01: 32 ms. 05: 120 ms
02: 64 ms. 06: 160 ms.
03: 80 ms. 07: 200 ms.
04: 100 ms. 08: 240 ms.
If no data is set, the default setting is 160 ms.
A
CM20
CM50
CM41
B
VOICE MAIL INTEGRATION

Table of Contents