– 750 – NWA-008845-001 Rev.5.0
32ch1011.fm
DESCRIPTION DATA
Assign VMS display, if required.
(1)
(2)
Y=0 By Character Code
X-XXXXXXXX: Station No.
564D53: VMS character code
(1)
(2)
Y=1 By Character
X-XXXXXXXX: Station No.
VMS (Character)
Assign the VMS station as the destination of a
call from a station which is set Message.
(1)
(2)
Y=15
00-63: Tenant No.
X-XXXXXXXX: VMS Station No.
Assign the MW lamp on a D
term
, if required.
(1)
(2)
Y=00
My Line No. + + Key No.
F1005
To access the VMS from DESKCON, assign
Out Pulse (DTMF signal) -short/long key.
(1)
(2)
Y=00
ATTCON No. (E000-E007) + + Key
No.
F6112: Out Pulse (DTMF signal)-short
F6113: Out Pulse (DTMF signal)-long
When Out Pulse (DTMF signal)-long is desig-
nated by CM90, assign the DTMF signal
width.
NOTE: When Out Pulse (DTMF signal)-
short is designated by CM90,
DTMF signal width is set to 128 ms.
(Fixed).
To allow Voice Mail Private Password:
(1)
(2)
Y=0
14: DTMF signal width
01-50: 64-3200 ms.
(64 ms. increments)
If no data is set, default setting is 512 ms.
Assign Password Privacy for the Tenant num-
ber of the VMS ports.
NOTE: This is effective for ports assigned
as VMS ports in CM13 Y=10.
(1)
(2)
Y=30
00-63: Tenant No. of VMS ports
0 : Allow
1 : Not allowed
B
CM77
CM51
CM90
,
,
CM41
CM65
END