Lists/Tables/Plans/Diagrams/Maintenance Verification
Maintenance table
439 / 476
Maintenance interval
Maintenance work
before har-
vest
start
daily
after the
first 50
oper. hrs.
every 50
oper. hrs.
after the
first 500
oper. hrs.
every 500
oper. hrs.
when
needed
annu-
ally
Axles
Check oil level X X
Change oil X X X
Hydraulic system
Clean hydraulic fluid cooler X X X
Check oil level X
Change hydraulic fluid X X
Clean intake sieves inside the fluid tank every 2 years
Hydraulic fluid filter (2 pieces)
replace filter elements
X X X X
Exchange filling cap hydraulic fluid tank
(ventilation and bleeding filter)
every 2 years
Check hydraulic lines for damage and
chafe marks
X X X X
Pneumatics
Replace air dryer cartridge X X
Drain compressed air reservoir X
Battery
Check acid level, possibly fill up liquid X X X
Check voltage, possibly recharge X X