CLI Reference GRTD Configuration Commands
without setting loopback, with loopback implemented through a
loopback adapter. Suppose that the test item ID in this module is 5.
ruijie# diagnostic loopback-test slot 1 port range
1-10 loopback no
ruijie# diagnostic start slot 1 test 5
diagnostic packet
As a command for testing all packets in privileged EXEC mode, this command is used to
set the length of the test packet, number sent test frames, and timeout time for receiving
test frames, with tick as timeout time unit.
diagnostic packet [slot slot_id [sub_system subsys_id]] [length lengtn_size] [num
num_count] [time_out tick_count]
(Optional) Subsystem ID (value range: 0-1), whose
meaning is equivalent to cpu id in the show version
command.
(Optional) Length of test frame
(Optional) Number of test frames
(Optional) Timeout time for receiving test frames
This command has no default setting.
Use the diagnostic packet command to set related parameters
related to test frames.
This command is for test items for designing test frame receiving
and sending, such as port loopback test and channel test.