CLI Reference DAI Configuration Commands
DAI Configuration Commands
ip arp inspection vlan vlan-id
Use this command to enable the DAI inspection function of the specified VLAN. The no option of this
command disables the function of the specified VLAN. If the parameter vlan-id is neglected, the DAI
inspection function of all VLANs will be disabled.
ip arp inspection vlan vlan-id
no ip arp inspection vlan [vlan-id]
Parameter
description
Parameter
Description
vlan-id
VLAN ID
Default
The DAI inspection function of all VLANs is disabled.
Command
mode
Global configuration mode.
Usage
guidelines
To execute this command, enable the DAI function firstly.
Examples
The following configuration is to check the ARP message received
from VLAN 1.
Ruijie(config)# ip arp inspection
Ruijie(config)# ip arp inspection vlan 1
Related
commands
Command
Description
show ip arp
inspection vlan
Show the information of the DAI inspection
function of the specified VLAN.
ip arp inspection trust
Use this command to configure the L2 port to a trusted port.The no option of this command will restore
the L2 port to a untrusted port.
ip arp inspection trust
no ip arp inspection trust
Default
configuration
The L2 port is a untrusted port.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruijie RG-S2600G-I Series and is the answer not in the manual?

Ruijie RG-S2600G-I Series Specifications

General IconGeneral
BrandRuijie
ModelRG-S2600G-I Series
CategorySwitch
LanguageEnglish

Related product manuals