CLI Reference VSU Configuration Commands
Guidelines
Configuration
Examples
Example 1 checks the configuration and status of the dual-active detection.
Ruijie# show switch virtual dual-active summary
BFD dual-active detection enabled: Yes
Aggregateport dual-active detection enabled: No
Interfaces excluded from shutdown in recovery mode:
GigabitEthernet 1/0/3
GigabitEthernet 1/0/4
In dual-active recovery mode: No
Example 2 checks the configuration information of BFD dual-active detection.
Ruijie# show switch virtual dual-active bfd
BFD dual-active detection enabled: Yes
BFD dual-active interface configured:
GigabitEthernet 1/0/1: UP
GigabitEthernet 2/0/2: UP
Example 3 checks the status of AP-based dual-active detection.
Ruijie# show switch virtual dual-active aggregateport
Aggregateport dual-active detection enabled: Yes
Aggregateport dual-active interface configured:
AggregatePort 1: UP
GigabitEthernet 1/0/1: UP
GigabitEthernet 2/0/1: UP
GigabitEthernet 1/0/2: UP
GigabitEthernet 2/0/2: UP
DAD relay enable AP list:
AggregatePort 1
Related
Commands
Command
Description
dual-active detection
Turn on the dual-active detection switch.
dual-active interface
Configure AP-based dual-activedetection
interfaces.
dual-active bfd interface
Configure BFD dual-active detection interfaces.
dual-active exclude interface
Configure the exclude interface.
Platform
Description
N/A
show switch virtual link
Show VSL status information.
show switch virtual link [ port ]