CLI Reference Guide SRM Configuration Commands
falling-waterline-value [interval interval-value]]
no {critical | major | minor}
Parameter
description
Parameter
Description
rising
Rising waterline.
rising-waterli
ne-value
Rising waterline value (unit: percent;
range: 1-100).
interval-value
Holding time, with unit being second,
minimal value being 5s and maximal
value being 86400s (24 hours).
falling
Falling waterline.
falling-waterli
ne-value
Falling waterline value (1-100); the
falling value must be less than the rising
value.
no
Remove the waterline.
Default
N/A
Command
mode
owner-memory or owner-cpu configuration mode
Usage
guidelines
Caution
The rising waterline of major must
be greater than that of minor, and
the rising waterline of critical must
be greater than that of major.
Examples
Example 1: Configure critical waterline.
Ruijie(config-srm-policy)#memory
Ruijie(config-owner-memory)#critical rising 80
falling 15 interval 10
Related
commands
Command
Description
resource manager
Enter the SRM configuration
mode.
policy policy-name
[global]
Create the policy and enter the
SRM-policy configuration mode.
memory
Enter the owner-memory
configuration mode.
cpu
Enter the owner-cpu configuration
mode.