317
[ESC+FX] DataMatrix (ECC200) Sequential Number
(Compatible command)
ESC FX ParameterHexadecimal code
<1B>
16
<46>
16
<58>
16
aaabcccdddeee
Initial value Nil
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range and term of
command
Valid range between
items
The set parameter becomes invalid.
[Function]
Specifying sequential number for DataMatrix.
[Format] (Sequential number part)
<FX>aaabcccdddeee
• Parameter
a [Number of duplication to print]
Valid Range
  
:
  
001 to 999
b [Flag of increase and decrease]
+ : Increment
- : Decrement
c [Number of increase and decrease]
Valid Range
  
:
  
001 to 999
d [Specification of digit position]
Valid Range : 001 to 999
e [Number of digit]
Valid Range
  
:
  
001 to 999
[Coding Example]
Number of duplication to print: 001, Flag of increase and decrease: +, Number of increase and
decrease: 001, Digit position: 005, Number of digit: 003
<A>
<V>100<H>200
<FX>001+001005003
<BX>01100202000000001
<DC>00006000
<Q>2
<Z>
[Precautions during use]
• This is the command of the old specification. Recommend the use of <2D50>.