385
[ESC+YR] Format Call
ESC YR ParameterHexadecimal code
<1B>
16
<59>
16
<52>
16
,aaa
Initial value Nil
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range and term of
command
Valid range between items The set parameter is valid until the next valid setting.
[Function]
Invoking and printing out the format registered with Registration of Format <YS>.
[Format]
<YR>,aaa
• Parameter
a   [Format registration Number]  =  Valid Range
 
:
 
1 to 999
[Coding Example]
<A>
<CC>1 
<YR>,1 
</D>,1,DEF 
</D>,2,78901 
</D>,3,49000238 
<Q>2 
<Z>
[Supplementary Explanation]
• This command cannot invoke multiple formats between Start of Data Transmission <A> and
End of Data Transmission <Z>.
• Use this command and Print of Field </D> as a pair.
• The error occurs when specifying unused or specifying the slot which the printer is allocated.
[Note]
• Do not turn the printer's power off when accessing to the memory. When the printer power is off
while memory accessing, the data in the accessed media may be corrupted.
Parent topic  Memory Card Command