EasyManua.ls Logo

SATO CL6NX - Timing Chart of Multiple Receive

SATO CL6NX
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
654
Timing chart of multiple receive
1) Normal process
2) Error process
Note:In this protocol, polling is performed for "ON" during the interval of 500 msec from the start of power supply up to reception of
first data item.
Printer
Printer Status
Receive/Analysis/Edit (3)
Power On
Printe
r
RD
SD
Initializin
g
STX.ETX (3)
Receive/Analysis/Edit (2)
Printing (1)
Online
Receive buffer near full state Receive buffer near full release
Offline
Printer Status
Press the LINE
button
Press the LINE
button
Receive/Analysis/Edit (1)
STX.ETX (1)
STX......ETX (4)
Receive/Analysis/Edit (4)
Printing (2)
500 msec
Printing (3)
STX.ETX (2)
* When the paper end error occurs, open the head, set label, close the head and feed.
Note: (1) The paper end error will be released when the head is closed.
(2) XOFF will be sent when data is received during an error.
RD
SD
STX......ETX (2)
Receive/Analysis/Edit (2)
Printing (1)
Online
Head open
Paper end error
Offline
Press the LINE button
Receive/Analysis/Edit (1)
STX..................ETX (1)
Printing (1)
Head close
Press the LINE button
*
Offline

Table of Contents

Other manuals for SATO CL6NX