EasyManua.ls Logo

SATO CL6NX - [DC2+PD] each Sensor Information Acquisition

SATO CL6NX
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
553
[DC2+PD] Each sensor information acquisition
Command DC2 PD Parameter
Hexadecimal code <12>
16
<50>
16
<44>
16
None
Initial Value None
When turning off the power -
Valid range -
Printer operation in
progress
The command can be received even during the printer
operation.
When acquiring label
sensor information
Commands are not accepted while acquiring sensor
information. ([NAK] reply)
Valid range and term of
command
Error The command can be received even if an error is
occurring.
[Function]
This command is used to acquire the information of each sensor. The sensor information
corresponds to the information immediately after the reception of the command.
[Format]
DC2 (12H) + PD
[Return data format (normal)]
[STX]a...a,b...b:c...c,(d...d:e...e) ... [ETX]
Symbol Parameter name Valid range
a Total number of data byte
* This is the total number of bytes after parameter
b. The delimiting comma between parameters a
and b, and the ETX are not included.
Data size from the first identifier until before
[ETX]
b(d) Sensor information name
* Text format
Refer to the sensor information data list.
c(e) Sensor information data
* Text format
Refer to the sensor information data list.
Data Example)
[STX]xx,IM:0.2/SL1.5,GAP:0.9/SL1.0...[ETX]
[Return data format (when a command error occurs)]