27
[ESC+Q] Print Quantity
ESC Q ParameterHexadecimal code
<1B>
16
<51>
16
aaaaaa
Initial value aaaaaa=1
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range and term of
command
Valid range between items The set parameter becomes invalid.
[Function]
Specifying the number of labels to print.
[Format]
<Q>aaaaaa
• Parameter
a [Number of labels to print] = Valid range: 1 to 999999
[Coding Example]
Number of labels: 2
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Supplementary Explanation]
• Print contents specified by Start of Data Transmission <A> and End of Data Transmission <Z>
are regarded as 1 label, and the number of reprints can be specified.
• Use this command prior to End of Data Transmission <Z>.
[Note]
• Reprint will be performed based on the specified print quantity. If specifying sequential
numbering command <F>, the value of sequential number that was set up for that field portion
will be printed.
• When this command is used in combination with Multiple Cutting <~>, the specified print
quantity multiplied by specified value for cutting becomes the number of labels to print.
Parent topic Control command