584
[DC2+PJ] RFID read (FeliCa) (CL4NX Only)
Command DC2 PJ Parameter
Hexadecimal code <12>
16
<50>
16
<4A>
16
,aa,bb
Initial value None
When turning off the
power
-
Valid range -
Printer operation in
progress
The command cannot be received during the printer
operation. ([NAK] return)
Valid range and term of
command
Error Commands can be received even if an error is
occurring.
[Function]
Returns inlet type and data of FeliCa Lite and FeliCa Lite-S to host.
[Function]
[DC2]PJ,aa(,aa),bb
[Parameters]
Symbol Parameter name Valid range Acquisition method
a Identifier F1: User data
(scratch pad + subtract register)
F2: ID data (IDm + PMm + ID block)
FA: All data (user data + ID data)
Refer to [Coding
sample] below.
b Options identifier NO: No option identifier
(When identifier H2, H3 is specified, it uses it.
The user data becomes ASCII expression if it
uses it when identifier H1 is specified.)
AS: Data output form = ASCII
HX: Data output form = HEX
* When the user data is sent back, it is reflected.
Two characters fixed
acquisition
[Return data format (normal)]
[STX]a…a,b…b[ETX]
[Return data]
Symbol Parameter name Valid range
a Total number of data byte
* This is the total number of bytes after parameter b.
The delimiting comma between parameters a and b,
and the ETX are not included.
* Data input and output form is which case of ASCII
or HEX, but, as for the unit, the value becomes
same for a byte.
Data size from the first memory data item until
before [ETX]
Maximum 4 digits