569
[DC2+PJ] RFID read (ISO/IEC15693) (CL4NX Only)
Command DC2 PJ Parameter
Hexadecimal code <12>
16
<50>
16
<4A>
16
,aa,bb
Initial value None
When turning off the
power
-
Valid range -
Printer operation in
progress
The command cannot be received during the printer
operation. ([NAK] return)
Valid range and term of
command
Error Commands can be received even if an error is
occurring.
[Function]
The data of the RFID tag corresponding to ISO/IEC15693 is sent back to the host.
[Function]
[DC2]PJ,aa(,aa)(,aa),bb
[Parameters]
Symbol Parameter name Valid range Acquisition method
a Identifier H1: USER data
H2: UID data
H3: Option flag data
(DSFID data
+
AFI data
+
EASbit)
HA: All data
USER data
+
UID data + Option flag data)
Refer to [Coding
sample] below.
b Options identifier NO: No option identifier
( When identifier H2,H3 is specified, it uses it.
The user data becomes ASCII expression if it
uses it when identifier H1 is specified.)
AS: Data output form = ASCII
HX: Data output form = HEX
AI: Read my-d in accordance with ISO, data
output form=ASCII
HI: Read my-d in accordance with ISO, data
output form=HEX
* When the user data is sent back, it is
reflected.
Two characters fixed
acquisition
[Return data format (normal)]
[STX]a…a,b…b[ETX]