568
[Sample of status reply]
When [DC2]PK is received using a tag with E200680612345678 for TID specified to return TID only.
â– Write successful (TID read successful)
[STX]25,1,N,ID:E200680612345678[CR][LF][ETX]
â– Write successful (TID read fail)
[STX]9,1,T,ID:[CR][LF][ETX]
â– Write fail (EPC write failed)
[STX]9,0,E,ID:[CR][LF][ETX]
[Supplemental explanation]
• The write status and EPC/TID is returned when [DC2]PK is received after RFID write.
• Although write is successful status will be returned without data if you fail to read EPC/TID since
EPC/TIC read will be done separately from write.
• Return data remains the same when EPC code write is specified without print data. Previous
value will be returned.
• For details on the return sequence, refer to EPC/TID return (UHF) <RU>.
Parent topic Common commands for all languages